Chevron (UK) Project

Chevron UK

 

 | 

Chevron Offshore Adhoc Troubleshooting Solar Generator

Chevron UK Graphs

 

PSW & GEs Machinery Diagnostic and Condition Monitoring Services draw on more than 40 years of offering unbiased diagnostic assistance regardless of manufacturer. We have a proven reputation that we continue to build upon with each project and consultation, ensuring that we will always “call it as we see it” no matter who manufactured, installed, maintained, or operated your machine.

 

Our team is comprised of more than 150 Machinery Diagnostic Engineers, globally distributed, with decades of experience and over 10,000 MDS projects executed.

In January 2016, PSW were asked to carry out an offshore machine diagnostic survey for Chevron UK on their Captain asset. Our Senior CM Engineer mobilised with a 32 channel data recorder for this generator vibration troubleshooting diagnostic scope.

 


Results from scope:

  • No unbalance of the rotor was evident through diagnostics when loading/unloading the Generator
  • New recommendations were givens for Alarms and Gap Voltages
  • The generator train was fully compliant with regulatory VA requirements/monitoring points.
  • 30-40% of procedures improved with better detail, limits and tolerances.

 Chevron UK 2-4-2Chevron UK 2-4-7

PSW Integrity understand the principles of equipment performance and reliability optimisation. Using our proven tools, training and processes, PSW Integrity effectively deliver, in an accelerated approach, the ability to manage customers assets in the most effective, efficient and safe manner throughout the asset lifecycle.

PSW have an in-depth knowledge of asset management implementation throughout decades of experience within the PSW group. We have equipment failure and PM data /case histories from hundreds of global projects and this knowledge and experience is vital to all of our clients to ensure they have world class best practice maintenance within, based on statistics, benchmarks and global standards.

Condition Monitoring
JDC Drilling Project
 

Comments

No comments made yet. Be the first to submit a comment
Already Registered? Login Here
Guest
Thursday, 29 June 2017

Captcha Image